{"product_id":"caldaia-a-gas-vaillant-atmotec-pro-vmw-240-5-3-metano-a-camera-aperta-erp","title":"VAILLANT AtmoTEC PRO VMW 240\/5-3 METHANE OPEN CHAMBER GAS BOILER - ErP","description":"\u003cp\u003e \u003cstrong\u003e\u003cspan style=\"font-size: medium;\"\u003eVAILLANT AtmoTEC PRO VMW 240\/5-3 METHANE OPEN CHAMBER GAS BOILER - ErP\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e \u003cspan style=\"font-size: x-large; font-family: 'arial black', 'avant garde';\"\u003e\u003cstrong\u003eTechnical features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\n\u003cli\u003e \u003cspan style=\"font-size: medium;\"\u003eFor heating and domestic hot water production\u003c\/span\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e \u003cspan style=\"font-size: medium;\"\u003eOpen chamber with natural draft\u003c\/span\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e \u003cspan style=\"font-size: medium;\"\u003eNominal heat input in domestic hot water kW 24\u003c\/span\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e \u003cspan style=\"font-size: medium;\"\u003eErP energy class (heating and DHW): class C\/B\u003c\/span\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e \u003cspan style=\"font-size: medium;\"\u003ePerformance stars (according to Dir. 92\/42EEC) - ***\u003c\/span\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e \u003cspan style=\"font-size: medium;\"\u003eDomestic hot water production (ΔT = 30K) 11.5 l\/min\u003c\/span\u003e\n\u003c\/li\u003e\n\n \u003cli\u003e\u003cspan style=\"font-size: medium;\"\u003eDomestic hot water comfort stars (prEN 13203) - **\u003c\/span\u003e\u003c\/li\u003e\n\n\u003cli\u003e \u003cspan style=\"font-size: medium;\"\u003eExpansion vessel capacity: 10 litres\u003c\/span\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e \u003cspan style=\"font-size: medium;\"\u003eDimensions (hxdxl) 800 x 338 x 440 mm\u003c\/span\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e \u003cspan style=\"font-size: medium;\"\u003eCode: 0010016269\u003c\/span\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e \u003cspan style=\"font-size: medium;\"\u003eVersion: \u003cspan style=\"color: #3366ff;\"\u003e\u003cstrong\u003eMETHANE or LPG\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003cp\u003e \u003cspan style=\"font-size: x-large; font-family: 'arial black', 'avant garde';\"\u003e\u003cstrong\u003eGeneral characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003cspan style=\"font-size: large; color: #3366ff; font-family: 'arial black', 'avant garde';\"\u003e\u003cstrong\u003eAtmoTEC PRO\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003cspan style=\"font-size: large; color: #3366ff; font-family: 'arial black', 'avant garde';\"\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\n\u003cli\u003e \u003cspan style=\"font-size: medium;\"\u003e\u003cem\u003eStandard wall-mounted boiler for heating and domestic hot water\u003c\/em\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e \u003cspan style=\"font-size: medium;\"\u003e\u003cem\u003eSanitary comfort even with low flow rates\u003c\/em\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\n \u003cli\u003e\u003cspan style=\"font-size: medium;\"\u003e\u003cem\u003eIntuitive display and simplified adjustments\u003c\/em\u003e\u003c\/span\u003e\u003c\/li\u003e\n\n\u003cli\u003e \u003cspan style=\"font-size: medium;\"\u003e\u003cem\u003eReduced electricity consumption\u003c\/em\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e \u003cspan style=\"font-size: medium;\"\u003e\u003cem\u003eSuitable for outdoor installations down to -10°C\u003c\/em\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e \u003cspan style=\"font-size: medium;\"\u003e\u003cem\u003eHigh efficiency pump.\u003c\/em\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e \u003cspan style=\"font-size: medium;\"\u003e\u003cem\u003eEnergy efficiency class C\/B\u003c\/em\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: medium;\"\u003e\u003cem\u003e\u003cbr\u003e\u003c\/em\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003chr\u003e\n\u003cul\u003e\u003cli\u003e \u003cspan style=\"font-size: medium;\"\u003e\u003cstrong\u003eThe atmoTEC pro\u003c\/strong\u003e VMW (heating and DHW production) are available in powers from 24 kW. atmoTEC pro was designed to offer the right balance between performance and comfort in both heating and domestic hot water production. Its simplicity of adjustment makes it the ideal boiler for all users.\u003c\/span\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e \u003cli\u003e\u003cspan style=\"font-size: medium;\"\u003e\u003cstrong\u003eAtmoTEC pro\u003c\/strong\u003e is equipped with an extremely simple interface with clear texts and a backlit display.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003e \u003cspan style=\"font-size: medium;\"\u003e\u003cstrong\u003eThe small dimensions of atmoTEC pro\u003c\/strong\u003e VMW 80cm high, 44cm wide and 35cm deep (identical to the previous version) allow installation in any environment. A new high efficiency pump and new electronics allow atmoTEC pro to consume very little electricity, guaranteeing significant savings throughout the year.\u003c\/span\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\n\u003chr\u003e\n\n\u003cp\u003e \u003cspan style=\"font-size: large;\"\u003e\u003cstrong\u003eEcodesign Directive (ErP) 2015\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan style=\"font-size: large; color: #3366ff;\"\u003e\u003cstrong\u003eHow to be ready for new EU legislation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan style=\"font-size: medium;\"\u003e\u003cem\u003e\u003cstrong\u003eWhat will happen from 26 September 2015?\u003c\/strong\u003e\u003cbr\u003e\u003c\/em\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n \u003cp\u003e\u003cspan style=\"font-size: medium;\"\u003eFrom this date it will no longer be possible to produce traditional forced draft boilers. Instead, it will be possible to continue to produce condensing boilers and traditional open chamber boilers equipped with high efficiency pumps and compliant with the \u003cem\u003e\u003cstrong\u003enew ErP requirements\u003c\/strong\u003e\u003c\/em\u003e such as emission, noise and efficiency levels. In particular, the installation of traditional open chamber boilers will only be possible to replace old boilers installed in multi-family buildings which discharge fumes into branched collective flues (CCR).\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan style=\"font-size: medium;\"\u003eProducts placed on the market before 09\/26\/2015 that do not comply with the requirements of the new directive, such as traditional forced draft boilers and boilers not equipped with a high efficiency pump, can still be purchased, sold and installed.\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cspan style=\"font-size: medium;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\n\u003cul\u003e \u003cli\u003e\u003cspan style=\"font-size: medium; color: #3366ff;\"\u003e\u003cstrong\u003eErP and ELD: what do they mean and how do they differ?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cspan style=\"font-size: medium;\"\u003e \u003c\/span\u003e\u003c\/h3\u003e\n\n\u003cspan style=\"font-size: medium;\"\u003e\u003cem\u003e\u003cstrong\u003eErP\u003c\/strong\u003e\u003c\/em\u003e : The EU has issued new obligations for energy-using products (ErP). The new directive, known as the Ecodesign directive, prescribes minimum efficiency requirements and emission limits for appliances that produce heating and domestic hot water. The Ecodesign directive is aimed at two categories of products relevant for installers and retailers in the sector:\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cul\u003e\u003cli\u003e \u003cspan style=\"font-size: medium;\"\u003e\u003cstrong\u003e\u003cem\u003eCategory 1\u003c\/em\u003e\u003c\/strong\u003e Includes space heating appliances: electric, gas, oil, combined boilers, heat pumps and cogenerators up to 400 kW.\u003c\/span\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\n\u003cbr\u003e\u003cul\u003e \u003cli\u003e\u003cspan style=\"font-size: medium;\"\u003e\u003cstrong\u003e\u003cem\u003eCategory 2\u003c\/em\u003e\u003c\/strong\u003e Includes appliances for the production of domestic hot water: electric, gas, oil, heat pumps for DHW, solar systems up to 400 kW and boilers up to 2000 litres.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cspan style=\"font-size: medium;\"\u003e \u003c\/span\u003e\u003cbr\u003e\u003cul\u003e \u003cli\u003e\u003cspan style=\"font-size: medium;\"\u003e\u003cem\u003e\u003cstrong\u003eELD:\u003c\/strong\u003e\u003c\/em\u003e in addition to the ErP directive, the EU has also introduced mandatory energy labeling for the same type of appliances up to 70 kW and boilers up to 500 litres. The energy labeling directive is called ELD and requires that new products and systems for heating and domestic hot water production are labeled with an indication of their energy efficiency class. By combining products and components, for example by adding a temperature control unit, it is possible to increase the energy classification of the system which will be calculated by the installer and indicated on the package label.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv\u003e\u003cspan style=\"font-size: medium;\"\u003e \u003c\/span\u003e\u003c\/div\u003e\n\n\u003cbr\u003e\u003cul\u003e\u003cli\u003e\u003cspan style=\"font-size: medium;\"\u003e\u003cstrong\u003eLet's take a look at the new labels...\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cspan style=\"font-size: medium;\"\u003e \u003c\/span\u003e\u003c\/h3\u003e\n\n\u003cul\u003e \u003cli\u003e\u003cspan style=\"font-size: medium; color: #3366ff;\"\u003e\u003cstrong\u003eWhen and how will the new rules apply?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv\u003e\u003cspan style=\"font-size: medium;\"\u003e \u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e\u003cspan style=\"font-size: medium;\"\u003eThe new rules will come into force on 26 September 2015. Until then, neither manufacturers, nor retailers or installers need to comply with the new provisions relating to \u003cem\u003e\u003cstrong\u003eEcodesign or labelling.\u003c\/strong\u003e\u003c\/em\u003e Once the new rules come into force, producers will only be able to produce products that comply with the new Ecodesign requirements, and will be obliged to provide an energy label to accompany the products.\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e\u003cspan style=\"font-size: medium;\"\u003e \u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e\u003cspan style=\"font-size: medium;\"\u003e \u003c\/span\u003e\u003c\/div\u003e\n\n\u003cul\u003e\u003cli\u003e\u003cspan style=\"font-size: medium; color: #3366ff;\"\u003e\u003cstrong\u003eWhy push condensation technology right away?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\n\u003cdiv\u003e\u003cspan style=\"font-size: medium;\"\u003e \u003c\/span\u003e\u003c\/div\u003e\n\n \u003cdiv\u003e\u003cspan style=\"font-size: medium;\"\u003eFor the energy requalification of individual homes, the 2007 Budget was extended until 31 December 2015. The request for a 65% tax deduction concerns, for example, the replacement of a traditional boiler with a condensing boiler.\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e\u003cspan style=\"font-size: medium;\"\u003e \u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e\u003cspan style=\"font-size: medium;\"\u003e \u003c\/span\u003e\u003c\/div\u003e\n\n\u003cul\u003e\u003cli\u003e\u003cspan style=\"font-size: medium; color: #3366ff;\"\u003e\u003cstrong\u003eWhat will Vaillant support?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\n\u003cdiv\u003e\u003cspan style=\"font-size: medium;\"\u003e \u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e\u003cspan style=\"font-size: medium;\"\u003e\u003cstrong\u003e\u003cem\u003e7 year guarantee\u003c\/em\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e\u003cspan style=\"font-size: medium;\"\u003e \u003c\/span\u003e\u003c\/div\u003e\n\n \u003cdiv\u003e\u003cspan style=\"font-size: medium;\"\u003eThe 7-year guarantee on new boilers is another excellent reason to offer Vaillant to your customers. Furthermore, know that by replacing a Vaillant boiler more than 15 years old with a new generation one, the warranty extension will be provided free of charge by the Vaillant Official Technical Assistance Center against a maintenance contract.\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e\u003cspan style=\"font-size: medium;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\u003chr\u003e\n\u003cp\u003e \u003cspan style=\"font-size: x-large; font-family: 'arial black', 'avant garde';\"\u003eProduct Warranty\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cspan style=\"font-size: medium;\"\u003eAll products for sale on our site are new and packaged. The warranty on this item is 24 months from the date of purchase.\u003c\/span\u003e\u003c\/p\u003e","brand":"Vaillant","offers":[{"title":"Default Title","offer_id":47743978930489,"sku":"CALD_38661M","price":507.15,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0847\/7189\/7657\/files\/immagine-1-caldaia-a-gas-vaillant-atmotec-pro-vmw-240-5-3-metano-a-camera-aperta-erp.jpg?v=1762784300","url":"https:\/\/climaconvenio.shop\/en\/products\/caldaia-a-gas-vaillant-atmotec-pro-vmw-240-5-3-metano-a-camera-aperta-erp","provider":"ClimaConvenienza","version":"1.0","type":"link"}