{"product_id":"caldaia-a-gas-ferroli-bluehelix-tech-rrt-24c-metano-o-gpl-completa-di-kit-scarico-fumi-new","title":"Caldaia a Condensazione Ferroli Bluehelix Tech Rrt 24C Metano con Kit Scarico Fumi","description":"\u003cp style=\"text-align: left;\"\u003e \u003cspan style=\"color: #ffffff; background-color: #ff0000;\"\u003eATTENTION\u003c\/span\u003e \u003cspan style=\"color: #ff0000;\"\u003eMethane, LPG, Propane air Ready through a simple configuration the boiler is able to operate on methane, LPG and propane air without the use of additional conversion kits. For information, contact your local authorized assistance center in advance\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan style=\"color: #3366ff;\"\u003eIN THE ABSENCE OF THIS ITEM, THE \u003cstrong\u003e\u003ca title=\"BLUEHELIX ALPHA 24\" href=\"https:\/\/climaconvenio.shop\/it\/caldaia-ferroli-a-condensazione-bluehelix-alpha-24c-completa-di-kit-scarico-fumi-metano-o-gpl-cod.-0tpf2awa-10850\/\" target=\"_blank\"\u003eBLUEHELIX ALPHA 24\u003c\/a\u003e\u003c\/strong\u003e MODEL WILL BE SHIPPED\u003c\/span\u003e\u003c\/p\u003e\n\n\u003chr\u003e\n\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/em\u003e \u003cstrong\u003eTechnical features\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e Model: Bluehelix Tech RRT 24C\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003cstrong\u003eEnergy rating\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e Heating energy efficiency class: A\u003c\/li\u003e\n\n \u003cli\u003eACS energy efficiency class: A\u003c\/li\u003e\n\n\u003cli\u003e ACS profile: XL\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003cstrong\u003ePerformance\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e Heating heat output: 5.0 ~ 20.4 kW\u003c\/li\u003e\n\n\u003cli\u003e Heating thermal power 80°C \/ 60°C: 4.9 ~ 20.0 kW\u003c\/li\u003e\n\n\u003cli\u003e Heating thermal power 50°C \/ 30°C: 4.9 ~ 20.0 kW\u003c\/li\u003e\n\n\u003cli\u003e DHW heat output: 5 ~ 25.0 kW\u003c\/li\u003e\n\n\u003cli\u003e DHW heating power: 4.9 ~ 24.5 kW\u003c\/li\u003e\n\n\u003cli\u003e Minimum efficiency 80°C \/ 60°C: 97.8%\u003c\/li\u003e\n\n\u003cli\u003e Maximum efficiency 80°C \/ 60°C: 98.0%\u003c\/li\u003e\n\n\u003cli\u003e Minimum efficiency 50°C \/ 30°C: 107.5%\u003c\/li\u003e\n\n\u003cli\u003e Maximum efficiency 50°C \/ 30°C: 106.1%\u003c\/li\u003e\n\n\u003cli\u003e G20 gas pressure: 20 bar\u003c\/li\u003e\n\n\u003cli\u003e G31 gas pressure: 37 bar\u003c\/li\u003e\n\n\u003cli\u003e NOx emission class: 6\u003c\/li\u003e\n\n\u003cli\u003e Heating operating pressure: 0.8 ~ 3 bar\u003c\/li\u003e\n\n\u003cli\u003e Maximum heating temperature: 90°C\u003c\/li\u003e\n\n\u003cli\u003e Heating expansion tank capacity: 8 litres\u003c\/li\u003e\n\n\u003cli\u003e Sanitary operating pressure: 0.3 ~ 9 bar\u003c\/li\u003e\n\n\u003cli\u003e Domestic water flow rate ∆t 25°C: 14 l\/min\u003c\/li\u003e\n\n\u003cli\u003e Domestic water flow rate ∆t 30°C: 11.7 l\/min\u003c\/li\u003e\n\n\u003cli\u003e Degree of protection: IP X5D\u003c\/li\u003e\n\n\u003cli\u003e Power (V,Hz, Ø): 220~240\/50\/1\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003cstrong\u003eDimensions and weight\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e Dimensions (HxWxD): 700x420x250 mm\u003c\/li\u003e\n\n \u003cli\u003eEmpty weight: 28.0 kg\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cdiv\u003e\n\n\u003cdiv\u003e\n\n\u003cdiv\u003e\n\n\u003cp\u003e \u003cstrong\u003e5 years without worries\u003c\/strong\u003e \u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003cdiv\u003e\u003cimg src=\"https:\/\/climaconvenio.shop\/pimages\/FCKeditorFiles\/Image\/Garanzia5Anni-.jpg\" alt=\"5 Year Warranty\" width=\"150\" height=\"142\" data-pagespeed-url-hash=\"3040870984\"\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003chr\u003e\n\n\u003cp\u003e \u003cstrong\u003eFerroli BLUEHELIX TECH RRT boiler\u003c\/strong\u003e \u003cem\u003eEcological wall-mounted condensing boilers with Ferroli Thermobalance™ combustion cell\u003c\/em\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cstrong\u003eThe evolution continues...\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e The range of generators is equipped with the tested AISI 304 stainless steel exchanger. Designed and built according to the new ErP directives for eco-friendly design and labelling, BLUEHELIX TECH RRT is placed at the top of its category. BLUEHELIX TECH RRT achieves one of the highest \u003cstrong\u003espace heating energy efficiency\u003c\/strong\u003e in the boiler category: \u003cstrong\u003eηs 94%\u003c\/strong\u003e . Furthermore, when combined with the external probe and the remote timer control, Romeo reaches system energy class A+\u003c\/p\u003e\n\n\u003cp\u003e \u003cstrong\u003eExtended warranty with the “5 YEARS WORRY-FREE” formula\u003c\/strong\u003e\u003c\/p\u003e\n\n \u003cp\u003eThe quality of Bluehelix TECH RRT is unquestionable, and Ferroli is ready to put it to the test by offering its customers extended warranty coverage which also ensures periodic maintenance and legal checks\u003c\/p\u003e\n\n\u003cp\u003e \u003cstrong\u003eTOP efficiency even on old systems\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e The exchanger of the \u003cstrong\u003eTHERMOBALANCE™\u003c\/strong\u003e thermal unit by Bluehelix TECH RRT in comparison with the more classic and widespread steel exchanger used in the past also by the Ferroli Group exclusively on a small series of boilers produced for the English market, and then immediately abandoned in favor of the evolution towards the proprietary steel exchanger used in the Bluehelix models\u003c\/p\u003e\n\n \u003cp\u003eThis geometry allows the exchanger of the THERMOBALANCE thermal unit to operate almost at maximum design efficiency even in conditions of partial clogging, while for the same quantity of deposits and sediments, for example due to installation on old systems, the exchanger tends to clog up much more quickly in the part in contact with the flame due to the reduced fluid passage area, which creates a real barrier of deposits that hinder heat exchange and reduce efficiency below nominal values .\u003c\/p\u003e\n\n\u003chr\u003e\n\n\u003cp\u003e \u003cstrong\u003ePluses of the product\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u0026gt; \u003cstrong\u003eBoiler\u003c\/strong\u003e with high thickness stainless steel primary exchanger, with increased passages (at the top of the category) to guarantee durability and reduced maintenance, maintains high efficiency even on old systems with oxidation and dirt\u003c\/p\u003e\n\n \u003cp\u003e\u0026gt; It achieves one of the highest \u003cstrong\u003eseasonal room heating efficiency\u003c\/strong\u003e in its category: \u003cstrong\u003eηs 94%\u003c\/strong\u003e and in combination with the modulating remote control and the optional external probe it reaches the highest efficiency class\u003c\/p\u003e\n\n\u003cp\u003e \u0026gt; \u003cstrong\u003eClass 6 NOx\u003c\/strong\u003e : already in line with the provisions of the ErP regulation, NOx emissions \u0026lt; 56mg\/kWh.\u003c\/p\u003e\n\n\u003cp\u003e \u0026gt; \u003cstrong\u003eMC \u003csup\u003e2\u003c\/sup\u003e\u003c\/strong\u003e : \u003cstrong\u003eM\u003c\/strong\u003e ulti \u003cstrong\u003eC\u003c\/strong\u003e ombustion \u003cstrong\u003eC\u003c\/strong\u003e ontrol, new combustion system with patented industrial-derived gas-adaptive technology for better adaptability of use as conditions of the gas network vary, such as fluctuations or reduced pressures.\u003c\/p\u003e\n\n\u003cp\u003e \u0026gt; \u003cstrong\u003eMGR\u003c\/strong\u003e : \u003cstrong\u003eM\u003c\/strong\u003e ethane \u003cstrong\u003eGpl\u003c\/strong\u003e \u003cstrong\u003eReady\u003c\/strong\u003e , through a simple configuration the boiler is able to operate on both methane and LPG without the use of additional conversion kits\u003c\/p\u003e\n\n \u003cp\u003e\u0026gt; Exclusive \u003cstrong\u003eexchanger-burner system with self-cooled door\u003c\/strong\u003e without insulators: simplifies maintenance and reduces costs thanks to fewer perishable parts.\u003c\/p\u003e\n\n\u003cp\u003e \u0026gt; \u003cstrong\u003eInstant production\u003c\/strong\u003e of domestic hot water with dedicated plate-based domestic hot water exchanger\u003c\/p\u003e\n\n\u003cp\u003e \u0026gt; \u003cstrong\u003eHydraulic connections\u003c\/strong\u003e covered by the boiler shell\u003c\/p\u003e\n\n\u003cp\u003e \u0026gt; Large \u003cstrong\u003emultifunction backlit graphic display\u003c\/strong\u003e for easy and correct parameter setting\u003c\/p\u003e\n\n\u003cp\u003e \u0026gt; \u003cstrong\u003eBy-pass\u003c\/strong\u003e as standard\u003c\/p\u003e\n\n\u003cp\u003e \u0026gt; Particularly suitable for operation in flues that require \"heavy\" ducting thanks to the approval for operation with 50mm diameter smoke exhausts\u003c\/p\u003e\n\n\u003cp\u003e \u0026gt; \u003cstrong\u003eFPS\u003c\/strong\u003e : \u003cstrong\u003eFume\u003c\/strong\u003e \u003cstrong\u003eProtection\u003c\/strong\u003e \u003cstrong\u003eSystem\u003c\/strong\u003e . The flue clapet valve inserted as standard on the boiler allows easy connection to pressurized collective flue systems\u003c\/p\u003e\n\n \u003cp\u003e\u0026gt; Designed to \u003cstrong\u003esimplify and facilitate\u003c\/strong\u003e normal \u003cstrong\u003emaintenance and cleaning\u003c\/strong\u003e operations\u003c\/p\u003e\n\n\u003cp\u003e \u0026gt; \u003cstrong\u003ePredisposition for solar systems\u003c\/strong\u003e : predisposed for the production of domestic hot water combined with solar panel systems\u003c\/p\u003e\n\n\u003cp\u003e \u0026gt; \u003cstrong\u003eECO function\u003c\/strong\u003e in domestic hot water for greater savings in periods of low use of hot water\u003c\/p\u003e\n\n\u003cp\u003e \u0026gt; \u003cstrong\u003e3-star certified comfort\u003c\/strong\u003e in sanitary production according to EN 13203\u003c\/p\u003e\n\n\u003cp\u003e \u0026gt; \u003cstrong\u003eSliding temperature operation\u003c\/strong\u003e via optional external probe\u003c\/p\u003e\n\n\u003cp\u003e \u0026gt; Low consumption modulating heating circulator\u003c\/p\u003e\n\n\u003cp\u003e \u0026gt; \u003cstrong\u003eDigital flame control\u003c\/strong\u003e with three re-ignition attempts in case of functioning block due to lack of flame detection, \u003cstrong\u003eonly for methane operation\u003c\/strong\u003e\u003c\/p\u003e\n\n \u003cp\u003e\u0026gt; \u003cstrong\u003ePlace of installation\u003c\/strong\u003e : also outdoors in a partially protected place up to -5°C as standard and up to -15°C with the aid of the optional antifreeze heater kit\u003c\/p\u003e\n\n\u003chr\u003e\n\n\u003cp\u003e \u003cstrong\u003eInnovative Ferroli THERMOBALANCE \u003csup\u003eTM\u003c\/sup\u003e heating group in its 5 elements\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e Ferroli oriented the design of the Bluehelix TECH RRT combustion cell and exchanger in order to maximize its functional advantages and construction robustness, as well as ease of maintenance: the single-circuit design ensures that any air bubbles in the system do not remain trapped in the exchanger, and makes cleaning as easy as possible with chemical washing, unlike spiral exchangers with double parallel circuits in which if only one of the circuits becomes clogged, chemical washing is much more laborious.\u003c\/p\u003e\n\n\u003col\u003e\n\n\u003cli\u003e \u003cstrong\u003eSingle-circuit stainless steel exchanger with high passages\u003c\/strong\u003e , resistant to clogging and easy to clean\u003c\/li\u003e\n\n \u003cli\u003e\n\u003cstrong\u003eSelf-cooled\u003c\/strong\u003e burner door without insulating panel\u003c\/li\u003e\n\n\u003cli\u003e Exclusive special \u003cstrong\u003ehemispherical stainless steel burner\u003c\/strong\u003e with \u003cstrong\u003elong-life gasket\u003c\/strong\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003e Intelligent \" \u003cstrong\u003eGas-adaptive\u003c\/strong\u003e \" system derived from industrial boilers, which monitors and self-stabilizes combustion as gas + fume conditions vary\u003c\/li\u003e\n\n\u003cli\u003e Offset fan, to facilitate \u003cstrong\u003emaintenance of the heating unit without dismantling.\u003c\/strong\u003e Integrated smoke \u003cstrong\u003eanti-return valve\u003c\/strong\u003e for connection to CCS\u003c\/li\u003e\n\n\n\u003c\/ol\u003e\n\n\u003cp\u003e \u003cstrong\u003eThe engine\u003c\/strong\u003e \u003cem\u003eCombustion cell\u003c\/em\u003e\u003c\/p\u003e\n\n\u003cp\u003e The tube that constitutes the BLUEHELIX TECH RRT exchanger is made of \u003cstrong\u003eAISI 304 stainless steel\u003c\/strong\u003e , a material that allows for the creation of an \u003cstrong\u003eextremely smooth surface\u003c\/strong\u003e , therefore less susceptible to encrusting agents and deposits.\u003c\/p\u003e\n\n\u003cp\u003e \u003cstrong\u003eTOP silence\u003c\/strong\u003e \u003cem\u003eThe new design for comfort\u003c\/em\u003e\u003c\/p\u003e\n\n \u003cp\u003eThe particularly careful design of BLUEHELIX TECH RRT has allowed it to achieve significant values ​​in terms of silence and acoustic comfort, so much so that it would almost be difficult to distinguish the background noise of a home from the noise produced by the boiler during full operation. Even the boiler on\/off transients have been optimized according to acoustic comfort, so that the customer will no longer have to worry about understanding whether the boiler is on or off by its noise as on older generations of boilers. The project also took care of the design, creating a precious mantle in 3 removable pieces, which comes down to cover the pipe connections.\u003c\/p\u003e\n\n\u003chr\u003e\n\n\u003cp\u003e \u003cstrong\u003eRemote control\u003c\/strong\u003e \u003cem\u003eof the environment and climate\u003c\/em\u003e\u003c\/p\u003e\n\n \u003cp\u003eBLUEHELIX TECH RRT can be combined with a wide range of remote time controls that allow the adjustment and operation of the appliance remotely. The ROMEO series is made up of multiple models, with weekly or daily comfort programming and with the possibility of choosing for both between wired or wireless connection\u003c\/p\u003e\n\n\u003cp\u003e By connecting to the external probe, BLUEHELIX TECH RRT is able to vary the \u003cstrong\u003esystem temperature according to the external temperature\u003c\/strong\u003e measured on the basis of configurable climatic curves, guaranteeing the user greater comfort as external climatic conditions vary. This functionality is internal to the boiler's electronic board and therefore \u003cstrong\u003edoes not require the presence of a remote control\u003c\/strong\u003e , making configuration operations simpler in the event of replacement.\u003c\/p\u003e\n\n \u003cp\u003eROMEO's modulating function allows \u003cstrong\u003ethe boiler power to be modulated\u003c\/strong\u003e as the set \u003cstrong\u003eroom temperature value\u003c\/strong\u003e is reached. This improves the quality of comfort by eliminating heat peaks with consequent energy savings\u003c\/p\u003e\n\n\u003cp\u003e \u003cstrong\u003eBoiler control Control\u003c\/strong\u003e \u003cem\u003epanel and functions\u003c\/em\u003e\u003c\/p\u003e\n\n \u003cp\u003eThe control and management electronics allow the user to customize the operation of the appliance in order to manage \u003cstrong\u003eenvironmental comfort according to his needs\u003c\/strong\u003e . The key control panel and the simple LCD display make programming operations for the production of hot water, both for domestic hot water and for heating, extremely easy and intuitive. Thanks to the remote connection via bus this can also be done directly from the Romeo remote control. The board is protected by a fuse that is easily accessible thanks to the dedicated cover and the electrical connections benefit from a large, robust box, with easy-access connectors and numerous cable ties. The boiler is also designed to connect \u003cstrong\u003ea second room thermostat\u003c\/strong\u003e on the dedicated terminals to manage multi-zone mixing systems\u003c\/p\u003e\n\n\u003chr\u003e\n\n\u003cp\u003e \u003cstrong\u003eMC \u003csup\u003e2\u003c\/sup\u003e\u003c\/strong\u003e \u003cem\u003eMulti Combustion Control\u003c\/em\u003e\u003c\/p\u003e\n\n \u003cp\u003eThe electronics control the flame ionization current in order to guarantee \u003cstrong\u003eoptimal combustion\u003c\/strong\u003e as the air density or gas quality varies. The relationship between the air\/gas ratio and the flame ionization signal is used to control the air-gas ratio itself and therefore combustion. \u003cstrong\u003eMC \u003csup\u003e2\u003c\/sup\u003e : Multi Combustion Control\u003c\/strong\u003e , the new combustion system with patented \u003cstrong\u003egas-adaptive\u003c\/strong\u003e technology improves the adaptability of use as the conditions of the gas network vary\u003c\/p\u003e\n\n\u003cp\u003e \u003cstrong\u003eEasy Maintenance\u003c\/strong\u003e \u003cem\u003eHassle-free maintenance\u003c\/em\u003e\u003c\/p\u003e\n\n\u003cp\u003e At the time of the first maintenance, the technician can realize the care with which every detail has been designed to facilitate his work. Thanks to maximum accessibility of the main components, the “Thermobalance”tm thermal unit allows maintenance to be carried out with maximum precision and speed.\u003c\/p\u003e\n\n\u003cp\u003e Some examples:\u003c\/p\u003e\n\n \u003cp\u003e- Internal accessibility is favored by the \u003cstrong\u003e3-piece casing\u003c\/strong\u003e with removable sides.\u003c\/p\u003e\n\n\u003cp\u003e - The electrical box of the electronic board can be easily extracted from the chassis and attached to the side, leaving \u003cstrong\u003efree access to the internal parts\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e - The \u003cstrong\u003efan offset from the burner\u003c\/strong\u003e and placed underneath, must not be dismantled to access the steel burner-exchanger group\u003c\/p\u003e\n\n\u003cp\u003e - The \u003cstrong\u003eburner door\u003c\/strong\u003e is totally \u003cstrong\u003eself-cooled\u003c\/strong\u003e by air and therefore does not require an insulating panel, avoiding the risk of this being damaged or broken during disassembly for cleaning.\u003c\/p\u003e\n\n\u003cp\u003e - The \u003cstrong\u003eburner can be disassembled by loosening just 3 bolts,\u003c\/strong\u003e leaving free access to the stainless steel exchanger.\u003c\/p\u003e\n\n\u003cp\u003e - The \u003cstrong\u003eexchanger with extra-large passages\u003c\/strong\u003e is designed to challenge the hardest waters and is \u003cstrong\u003eeasily cleanable\u003c\/strong\u003e thanks to the non-collectorised single tube circuit.\u003c\/p\u003e\n\n \u003cp\u003e- The domestic water \u003cstrong\u003einlet filter\u003c\/strong\u003e can be \u003cstrong\u003eextracted\u003c\/strong\u003e extremely easily directly from inside \u003cstrong\u003ewithout having to remove the boiler's hydraulic connections\u003c\/strong\u003e .\u003c\/p\u003e\n\n\u003cp\u003e - Any disassembly and \u003cstrong\u003ereplacement of the plate exchanger\u003c\/strong\u003e occurs simply \u003cstrong\u003eby removing two Allen bolts\u003c\/strong\u003e accessible from the front\u003c\/p\u003e\n\n\u003chr\u003e\n\n\u003cp\u003e \u003cstrong\u003eSimplified replacement\u003c\/strong\u003e \u003cem\u003eSmoke exhaust ø 50 mm\u003c\/em\u003e\u003c\/p\u003e\n\n\u003cp\u003e The new boiler can also be installed with 50mm diameter ducting outlets. Particularly important in the \u003cstrong\u003ereplacement market\u003c\/strong\u003e in the frequent case of collective flues that require \u003cstrong\u003e\"heavy\" ducting\u003c\/strong\u003e where it is necessary to have a \u003cstrong\u003ehigh smoke expulsion capacity\u003c\/strong\u003e even with small diameters.\u003c\/p\u003e\n\n \u003cp\u003e\u003cstrong\u003eFPS\u003c\/strong\u003e .: \u003cstrong\u003eFume\u003c\/strong\u003e \u003cstrong\u003eProtection\u003c\/strong\u003e \u003cstrong\u003eSystem\u003c\/strong\u003e . The flue flap valve allows \u003cstrong\u003eeasy connection to pressurized collective flue systems\u003c\/strong\u003e . For installers, the collective pressurized pipe solution is more economical\u003c\/p\u003e\n\n\u003chr\u003e\n\n\u003cp\u003e \u003cstrong\u003eComfort \u0026amp; Safety\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e The designers have thought of a series of functions capable of guaranteeing the quality of the domestic water, the best power delivery to the heating system combined with a longer life of the appliance\u003c\/p\u003e\n\n\u003cp\u003e \u003cstrong\u003eStop and Go function\u003c\/strong\u003e\u003c\/p\u003e\n\n \u003cp\u003eWith the use of sanitary mixing taps, short or very short deliveries for quick rinses lead to the start of the boiler ignition procedure which usually ends immediately. The continuation of these \" \u003cstrong\u003efalse starts\u003c\/strong\u003e \" can, in the long run, compromise the average life of the product. For this reason, BLUEHELIX TECH RRT provides an electronic parameter through which it is possible to delay the ignition of the burner by activating it only in the event of actual domestic hot water withdrawals\u003c\/p\u003e\n\n\u003cp\u003e \u003cstrong\u003eSun Easy function\u003c\/strong\u003e\u003c\/p\u003e\n\n \u003cp\u003eBLUEHELIX TECH RRT was designed to be easily inserted into systems created with the latest technologies. The SUN EASY system uses electronics that \u003cstrong\u003esimplify the combination with both natural and forced circulation solar panels\u003c\/strong\u003e . Using a sensor located on the domestic hot water circuit, it continuously controls the temperature of the water preheated by the solar panels, providing for the burner to be turned on only if the latter drops below the level necessary to guarantee optimal comfort for the user\u003c\/p\u003e\n\n\u003cp\u003e \u003cstrong\u003eSanitary Eco-Comfort function\u003c\/strong\u003e\u003c\/p\u003e\n\n \u003cp\u003eIn ECO operation, the production of domestic hot water occurs according to traditional standards, allowing energy savings during periods of non-use. In COMFORT operation, thanks to the particular temperature maintenance system of the heat exchanger, \u003cstrong\u003ethe supply of domestic hot water becomes even quicker and more comfortable\u003c\/strong\u003e . Achieving maximum 3-star certified comfort. The efficiency and load profiles according to the ErP directive are at the top of the category\u003c\/p\u003e\n\n\u003cp\u003e \u003cstrong\u003eExternal installation and anti-freeze function\u003c\/strong\u003e\u003c\/p\u003e\n\n \u003cp\u003eTo make the most of the available spaces, the new BLUEHELIX TECH RRT 24C boiler can be installed recessed into the wall thanks to the special kit. For more critical installations, in completely uncovered places not protected from atmospheric agents, the \"painted cabinet\" kit is also available. In the event that the temperature in the boiler drops to 5°C, the burner automatically turns on and the circulator is activated in order to \u003cstrong\u003eprotect the appliance from damage caused by frost\u003c\/strong\u003e . This function is active with the boiler powered by the gas circuit and under electrical voltage\u003c\/p\u003e\n\n\u003chr\u003e\n\n\u003cp\u003e \u003cstrong\u003eProduct Warranty\u003c\/strong\u003e : All products on sale on our site are new and packaged. The warranty on this item is \u003cstrong\u003e24 months\u003c\/strong\u003e from the date of purchase.\u003c\/p\u003e","brand":"Ferroli","offers":[{"title":"Kit Fumi Coassiale","offer_id":56072114569596,"sku":"Bluehelix Tech RRT 24 Metano","price":717.15,"currency_code":"EUR","in_stock":true},{"title":"Kit Fumi Sdoppiato","offer_id":56072114602364,"sku":"Bluehelix Tech RRT 24 Metano1","price":717.15,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0847\/7189\/7657\/files\/immagine-1-caldaia-a-gas-ferroli-bluehelix-tech-rrt-24c-metano-o-gpl-completa-di-kit-scarico-fumi-new.jpg?v=1772464257","url":"https:\/\/climaconvenio.shop\/en\/products\/caldaia-a-gas-ferroli-bluehelix-tech-rrt-24c-metano-o-gpl-completa-di-kit-scarico-fumi-new","provider":"ClimaConvenienza","version":"1.0","type":"link"}